Test Programs . ADS

Reactor Coolant System Automatic Depressurization Tests

In Casaccia, Italy, full-scale, full-flow tests were done on the automatic depressurization system (ADS). These tests went through two major phases. In the first phase, 21 depressurization runs were conducted. The second phase included 24 depressurization tests. The test results matched computer modeling of the ADS performance.